Signum Power boiler is intended to top combustion of fuels. This model enables us to burn coal and powdered coal up to 30% humid (also seasoned wood is permitted). Signum Power boiler enables us to load the entire burning chamber which translates into approx. 24 h of regular combustion (this time depends on many factors, among others, insulation of a building, ambient temperatures etc.). After end of the load it is recommended to empty the chamber and then, to re-load fuel and to fire it.
Boiler’s exchanger is made from certified boiler steel 265GH, 6 mm and it is equipped with a water grate and a mobile steel grate applied to remove ash from the fireplace. Boiler’s exchanger is protected, from the outside, by means of anti-rust paint and it is also finished by mineral wool insulation in order to minimize loses. All housings of the boiler are powder coated.
Advantages of the boiler
– slow-burning
– modern, micro-processor control system EKOSter 400 – it controls process of burning and makes the boiler does not require regular supervision and service.
– numerous points via which air is supplied to a fireplace
– mobile grates
– top burning system
– possibility to apply all solid fuels
– 48 month of guarantee for heat exchanger tightness,
– 24 month guarantee for remaining elements.
Equipment:
– boiler operation control set (a controller and a fan)
– comfortable inclined hopper
– analogous thermometer
– universal door (left-right))
– water grate
– exchanger made from certified boiler steel, cat. P265GH, 6 mm,
– protective measures acc. to a standard PN-B-02413:1991
– right angle connection with a chimney
Signum Power | 10 kW | 13 kW | 17 kW | 23 kW | 28 kW | 35 kW | |
Extent of heating (kW) | 3,0-10 | 3,6-13 | 4,5-17 | 6,0-23 | 7,5-28 | 10,5-35 | |
Heating area (m2) | 1,0 | 1,4 | 1,8 | 2,4 | 2,9 | 3,5 | |
Area of heated rooms (m2) | do 100 | do 120 | do 150 | do 200 | do 250 | do 350 | |
One-time fuel load (kg) | ~21 | ~27 | ~30 | ~40 | ~50 | ~71 | |
Max. working pressure (bar) | 1,5 | ||||||
Required fumes draught (Pa) | 20 | 22 | 23 | 26 | 28 | 31 | |
Mass of a boiler (kg) | 250 | 272 | 320 | 337 | 373 | 420 | |
Water capacity of the boiler (L) | 40 | 46 | 52 | 65 | 72 | 80 | |
Section of chimney (cmxcm) | 14×14 | 16×16 | 16×16 | 16×16 | 16×16 | 18×18 | |
Diameter of chimney (ø mm) | 160 | 180 | 180 | 180 | 180 | 200 | |
Min. height of chimney (M) | 5,5 | 6 | 7 | 7,5 | 8 | 9 | |
Width (mm) | 575 | 575 | 625 | 675 | 725 | 725 | |
Depth (mm) | 975 | 1192 | 1192 | 1192 | 1192 | 1192 | |
Height (mm) | 1080 | 1130 | 1130 | 1130 | 1130 | 1340 | |
Diameter of supply and return | 1,5’’ | ||||||
Temp. of water at the supply min./max. (oC) | 65/85 | ||||||
A – height of bottom edge of smoke conduit (mm) | 563 | 613 | 700 |