Hydra Basic Mini

Hydra Basic mini boiler, 10 kW, with a screw conveyor, cooperates with gravity central heating water system or open circuit forced circulation.

Hydra Basic boiler mini meets expectations of owners of small buildings who want to appreciate comfort of a boiler with a feeder.

Equipment of the Hydra Basic mini boiler METALBET

– fireplaces – automatic (granulation of fuel up to 25mm) and traditional (every type of solid fuel),
– factory mounted blowing system along with control,
– universal feeder (left, right)

– mobile water grates

– universal door (right/left),

– electronic thermometer,
– cast iron burner and screw

– advanced controller servicing 2 pumps,

– exchanger made from certified boiler steel, cat. P265GH, 6 mm,,
– 45o angle connection with a chimney

Advantages of Hydra Basic Mini METALBET

– retort to burn eco-pellet
– small dimensions of the boiler enable assembly and operation in a small boiler room
– possibility to apply all types of solid fuels such as eco-pellet, energy powder, nut shells, hard coal, wood etc.,

– reliable structure – the tank is made from certified steel boiler sheet, cat. P265GH, 6 mm thick, protected from thermal loss by insulation,

– great thermal-insulation rate and mechanical durability – thermal insulation made from non-asbestos mineral wool 40 mm thick. enables to limit thermal loss maximally,

– full safety of use,

– high aesthetics and interesting colors (gray-orange),

– low price and high quality of the product,,
– 60 month of guarantee for heat exchanger tightness,

– 24 month guarantee for remaining elements

Hydra Basic Mini 10
Extent of heating (kW) 3,5-10
Heating area (m2) 1,0
Area of heated rooms (m2) do 100
One-time fuel load (kg) 105
Max. working pressure (bar) 1,5
Required fumes draught (Pa) 23
Mass of a boiler (kg) 389
Water capacity of the boiler (L) 54
Section of chimney (cmxcm) 14×14
Diameter of chimney (ø mm) 180
Min. height of chimney (m) 6
Width (mm) 1020
Depth (mm) 820
Height (mm) 1354
Boiler effectivity 87,2%
Diameter of supply and return Dn (cal) 1,5
Temp. of water at the supply min./max. (oC) 65/85
Power (V/Hz) ~230/50
Power consumption (W) 177
A – height of bottom edge of smoke conduit (mm) 1354

I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.