Aqua Classic

Aqua Classic boiler is characterized by high thermal efficiency. The model in question is equipped with a large load chamber which is easily accessed. Additional advantage of the boiler is that it is ready to be equipped with a fan along with a controller.
Central heating boiler Aqua Classic cooperates with a gravity central heating water system or open circuit forced circulation.

This model is manufactured in 8 power versions adjusted to areas which it is intended for. Small dimensions of the boiler make it is perfect for tiny rooms.

Varied types of the boilers meet expectations of owners of single family houses, smaller and larger ones, as well as owners of utility buildings and workshops, skyscrapers, factories and other buildings.

Parts of the Aqua Classic boiler METALBET

  • large load chamber,
  • mobile water grates,
  • universal door (right/left),
  • exchanger made from certified boiler steel, cat. P265GH, 6 mm,
  • protective measures acc. to a standard PN-B-02413:1991,
  • analogous thermometer,
  • hatch of a draught regulator – it enables to regulate quantity of air, which must be provided in order to keep desired temperature.

Aqua Classic boiler is adjusted to mount air regulator and a blowing set along with a control unit (additional option).

Advantages of Aqua Classic METALBET
– possibility to apply all types of solid fuels such as eco-pellet, energy powder, nut shells, hard coal, wood etc.
– reliable structure – the boiler is made from a high-quality, certified steel boiler sheet, cat. P265GH, 6 mm thick.,
– great thermal insulation and mechanical durability,
– simple fuel loading,
– universal door (right/left),
– draught regulator enables to adjust air which must be provided in adjusted quantity in order to keep desired temperature,

– 48 month of guarantee for heat exchanger tightness,

– 24 month guarantee for remaining elements,

– right angle connection with a chimney

Aqua Classic 8kW 10kW 12kW 15kW 20kW 25kW 30kW 35kW
Extent of heating (kW) 2,4-8 3,0-10 3,6-12 4,5-15 6,0-20 7,5-25 9,0-30 10,5-35
Heating area (m²) 0,80 1,0 1,2 1,5 2,0 2,5 3,0 3,5
Area of heated rooms (m²) do 80 do 100 do 120 do 150 do 200 do 250 do 300 do 350
One-time fuel load (kg) ~16 ~21 ~27 ~30 ~40 ~50 ~63 ~71
Max. working pressure (bar) 1,5
Required fumes draught (Pa) 18 20 22 23 26 26 30 31
Mass of a boiler (L) 194 218 262 283 306 332 364 392
Water capacity of the boiler (L) 32 35 41 54 65 76 88 115
Section of chimney (cm x cm) 14×14 14×14 16×16 16×16 16×16 16×16 18×18 18×18
Diameter of chimney (Ø mm) 160 160 180 180 180 180 200 200
Min. height of chimney (M) 5,5 5,5 6 7 7,5 8 8 9
Width (mm) 538 538 538 588 638 686 686 736
Depth (mm) 668 778 793 793 793 793 793 793
Height (mm) 1265 1358 1429 1429 1429 1428 1638 1638
Diameter of supply and return 1,5”
Temp. of water at the supply min./max. (ºC) 65/85
A – height of bottom edge of smoke conduit (mm) 922 996 1065 1274

A-Classic-717x1024

I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.